Electrical Combinet Air Conditioner Operators Manuel
Contents |
---|
COMPRESSOR |
CONDENSER AND EVAPORATOR AIR CARRIERS |
Principles of Operations |
News 15.08.2021 14:24 | Last Update | Reading Time 5 Minute
The Electrical Cabinet Air Conditioner Operators Manual is used to package electronic components. Built to cool and dehumidify the indoor environment. It keeps the air in the indoor environment cool and clean. It cools the interior environment of the cabinet and enclosures. Thus, it offers a long life by cleaning the ambient atmosphere.
COMPRESSOR
Hermetically sealed electrical Cabinet Air Conditioner manual compressor does not require maintenance. It can only work without any problems for years with the lubrication process performed during production. One of the things to do is not to loosen, remove and damage the access connection covers. Damage to the seals on the access connection covers is not covered by the warranty.
CONDENSER AND EVAPORATOR AIR CARRIERS
It has impeller motors inside and does not require maintenance. The bearings contained in it must be lubricated throughout their lifetime. It is necessary to replace the blower when one or all of the ambient wheels break down. But there is no need to remove the air conditioner from the Cabinet to replace the blower.
Principles of Operations
Electric Cabinet Air Conditioner Manual, this system, which allows you to adjust the temperature in a closed environment and remove moisture, also controls the air against dust, smoke, abrasives and other pollutants. These devices use closed-circuit cooling systems. It provides air purification by increasing Optimum performance. Two different circulation systems are available. One of the circulation systems, the internal system cools the air in the cabin and removes moisture. It isolates all sensitive electronics from the environment, ensuring their protection. The external system drains heat from electronic devices and uses the air or water present in the circulation during this process. Excess heat is removed from the environment thanks to the vapor compression and cooling cycle. In hermetically sealed cooling systems or air-cooled systems, cleaning the air and preserving the existing heat is provided. The indoor hot air is drawn from the evaporator coil, where it is cooled, humidified and returned. When any casing moisture accumulates on the evaporator coil, this moisture is collected in the condensate tray. After that, the condensate is removed from the drainage pipe to the evaporator. Condensate evaporates in the condensate evaporator. After evaporation, it is released into the ambient air by the condenser wheel. The heat extracted from the evaporator coil is transferred to the condenser coil along with the compressed refrigerant. Ambient air is then passed through the condenser coil, absorbing the heat and discharging it into the environment. The electric Cabinet Air Conditioner Manual should operate continuously depending on ambient temperatures when appropriately sized. It must also maintain a 75°F to 115 ° f enclosure temperature.